Schüco Façade System FWS 60.HI

Highly thermally-insulated mullion/transom façade with 60 mm face width for a variety of solutions

The highly thermally insulated Schüco FWS 60.HI (High Insulated) façade system offers high flexibility and attractive design options for highly thermally insulated façades and skylight areas in a narrow steel look, including optimised fabrication and installation processes. Thanks to a broad system range, solutions for the most varied requirements and applications can be implemented.

A transparent system solution integrated in the profile for spandrel safety barriers blends seamlessly and elegantly into the external façade appearance. The required safety barrier loading for floor-to-ceiling opening units and low spandrel heights can be implemented with consistent profile face widths and a continuous profile.

In terms of design freedom, the mullion/transom façade with 60 mm face width offers a large selection of pressure plates and façade cover caps as well as the option of being combined with Schüco window, door and sliding systems.

System-optimised components guarantee the simple and reliable integration of electrical components, e.g. for automated Schüco door or sun shading installations.

  • Highly thermally insulated mullion/transom façade system with 60 mm face width
  • Profile-integrated spandrel safety barrier for floor-to-ceiling opening units and low spandrels ensure a minimalist and harmonious façade appearance
  • Wide selection of pressure plate profiles and façade cover caps, also in stainless steel, for the most varied of design requirements
  • Integration of diverse insert units from Schüco window, doors and sliding systems
Min. face width
60 mm
Max. glass/panel thickness
62 mm
Uf value of frame (≥)
0.84 W/(m²·K)
Max. sound reduction index Rwp
46 dB(A)
Air permeability
AE
Watertightness
RE 1200
Burglar resistance
Up to RC3
Wind load resistance
2.0/3.0 [kN/m²]
CE marking
Yes
Min.-max. glass/panel thickness
22...62 mm
Surface finishes
Powder, Anodised, Paint
Drainage levels
3
Integrated sun shading
Yes
Suitable for safety barrier loading
Yes
Min.-max. system basic depth
6...255 mm
Max. weight
1080 kg
Impact resistance
I5/E5
Bullet resistance
Up to FB 4
Min. system basic depth
6 mm
Max. system basic depth
255 mm
Min. basic depth of mullion
50 mm
Max. basic depth of mullion
250 mm
Min.-max. basic depth of mullion
50...250 mm
Max. unit weight
1080 kg
Face width of pressure plate / cover cap profile
60 mm
Face width, outside
60 mm
Face width, inside
60 mm
Face width of mullion
60 mm
Face width of frame
60 mm
Face width of transom
60 mm
Min. glass/panel thickness
22 mm
Max. glass/infill weight
1080 kg
Installation angle
2-105 °
Polygon façade angle
35 °
Skylight construction, min. vert. incline
2 °
Skylight construction, max. vert. incline
90 °
Skylight construction, min.-max. vert. incline
2...90 °
Skylight construction
Yes
Drainage
Yes
DIN EN 62561 lightning protection
Yes
Sun shading attachment
Yes
Passive house compliant
Yes
Recyclable
Yes
Standards
DIN EN 1627, EN ISO 10077, DIN EN 13830, General building authority approval
AAMA certified
Yes
CWCT certified
Yes
Building authority approval
Yes
European Technical Assessment
Yes
Min.-max. face width
60 mm

Schüco FWS 60.HI, highly thermally insulated aluminium add-on construction on a steel load-bearing structure
(with brackets)
As a mullion/transom construction for multi-storey façades with a 60 mm external face width.

Design features:
The construction must have HI isolators (isolator with foam profile) to suit the infill thicknesses. The aluminium pressure plates also have additional thermal insulation tape.

Load-bearing structure:
In terms of the fabrication and installation tolerances, the substructure for the add-on construction described below must be designed, deviating from DIN, in accordance with the specifications of the system provider for the add-on construction.
An agreement regarding the tolerances of the substructure to be adhered to must be made between the contractors of both trades immediately after the contract has been awarded.

Selection
The load-bearing structure of the façade construction must be fabricated from steel rectangular profiles/steel supports.
or
The load-bearing structure of the façade construction is fabricated from steel rectangular profiles/steel supports produced by the customer.
End
The load-bearing steel construction is on the inside. The welded construction must be calculated and executed in accordance with DIN 18 800. The corrosion protection of steel structures must be in accordance with DIN 55 928. The steel profiles must be prepared for paint to be applied by others. The contractor for the painting work must be advised that the profile surfaces must be cleaned and primed before being painted. The space between the load-bearing structure and the add-on construction must be closed off using a gasket.
The glazing system is formed by mullion and transom profiles with C-shaped locating grooves for attachment to the load-bearing structure, as well as aluminium cover caps and/or pressure plates. The gasket locating groove of the transoms overlaps the gasket locating groove of the mullions. The overlap area must be sealed with appropriate seals. The glazing system is attached to the load-bearing structure by means of stainless steel fixing brackets. The maximum fixing intervals must be calculated in accordance with the system manufacturer’s size tables.

Glazing / insert units:
All glazing, even in the insert units, lies in the same plane.
The glazing gaskets made from weather-resistant, black EPDM on the room side are of different depths in the mullions and transoms (6 mm offset).
Two individual gaskets made from weather-resistant, black EPDM, with a height of 3.5 mm, are positioned on the outside. Cruciform gaskets made from EPDM must be used where mullions and transoms join.
In principle two individual gaskets and butyl tape must be used for roof glazing.

Ventilation:
Rebate base ventilation and vapour pressure equalisation take place at all four corners of each module field into the mullion rebate.
For field drainage and ventilation, appropriate openings must be made in the aluminium pressure plates, cover caps and gaskets.

Profile face widths:
Mullion, transom, cover caps 60 mm

Profile basic depths:
Add-on mullion 22 mm
Add-on transom 28 mm
Cover cap (mullion) rectangular 20 mm
Cover cap (transom) rectangular 15 mm

Similar Products

Explore Art Home

Projects

Products

About us

Contact

Partners

En

/

De

Choose your area of interest

Homeowners

Architects

Choose your material

Choose your material

Choose your material

Overview of PVC products

Overview of aluminium products

Request a quote

Tell us what you need and we’ll get back to you with a custom offer.

Start Your Project

Briefly describe your project. We’ll get back to you shortly